Product Details
Description:
The explosion-proof zirconia oxygen analyzer not only is a practical and reliable automatic analytical instrument and also the explosion-proof zirconia oxygen analyzer has the characteristics of high sensitivity, good reproducibility and stability, wide range, automatic switching, fast response and continuous online measurement. Therefore, the Explosion-proof Zirconia Oxygen Analyzer can quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces that to achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.
Application
The explosion-proof zirconia oxygen analyzer is mainly used in:
★ Coal-fired power plants
★ Waste incineration power plants
★ Biomass power plants
★ Sulfuric acid plants
★ Chemical plant boilers
★ Hazardous waste treatment boilers
★ Heating station boilers
★ Steel plants, steel mills
★ Petroleum Pipeline pressure station boilers and other fields
Main Features
★ No special ground wire required.
★ High accuracy and wide range ratio.
★ Zirconia probe wear resistance and corrosion resistance.
★ Strong resistance to field interference.
★ Easy to install, the response is fast and widely used.
★ Convenient replacement of components, easy maintenance, and reduced use cost.
Specification
Items |
Specifications |
Oxygen concentration: |
0.001~100 vol% |
Output signal: |
4~20mA DC (maximum load resistance 750Ω) |
Setting range: |
0~20.6 vol% (0~30% can be set) |
Digital communications: |
Support Modbus 232/485 and Ethernet (selectable) |
Heating time: |
Approx. 20 min. |
Repeatability: |
±0.5vol% maximum value of set range. |
Zero drift: |
1.5 vol% maximum value of set range (60 days) |
Response time: |
Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing). |
Power supply: |
220±10%VAC |
Installation: |
Flange mounting |
Limit output: |
Provide settable upper and lower limit outputs (optional) |
Temperature control accuracy: |
0~700℃ (Floating temperature calculation)
|
Equipment system accuracy: |
±1%F.S. |
Digit display mode: |
4 bit LED nixie tube display |
Operation: |
Menu button operation |
Calibration operation: |
Three parameters on-line calibration |
Equipment power: |
Approx. 10W (Excluding heating power) |
Heating power: |
50W (average), able to supply maximum 150W power output |
Environmental conditions: |
Ambient temperature 0~70℃, relative humidity ≤ 90% |
Protection level: |
IP65 |
Electrical interface: |
M20 |
Explosion-proof level: |
EXdII ct6 GB (only for explosion-proof type product) |
Detector length:
180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)
(Note: Detector length is from the detector tip to flange)